PM-TT1R

single-channel PT100 RTD temperature transmitter PM-TT1R

The PM-TT1R reads one PT100 input and converts temperature to 0–5/10 V or 0–20/4–20 mA; temperature data is also available over RS485 Modbus RTU for a PLC or monitoring system.

  • RS485 communication
  • Modbus communication
  • Analogue output
  • One RTD sensor input: PT100; PT1000 available as an option
  • Published measurement range: −200 to +650 °C
  • 0–5 V, 0–10 V, 0–20 mA or 4–20 mA analogue output
  • RS485 Modbus RTU digital communication
  • 0.1 °C resolution in the catalogue; 50 Hz sample rate

18-month warranty

Device specifications

Technical specifications

Product type
Single-channel RTD temperature transmitter
Sensor input
One RTD input; PT100, with PT1000 listed as an optional catalogue configuration
Sensor wiring
Two-wire or three-wire
Sensor measurement range
−200 to +650 °C
Stated measurement accuracy
±0.5 °C
Resolution / sampling rate
0.1 °C / 50 Hz
ADC / analogue output resolution
15 bit / 14 bit, as published
Analogue output
0–5 V, 0–10 V, 0–20 mA or 4–20 mA
Communication output
RS485 with Modbus RTU
Supply / power consumption
24 V DC / 1.5 W
Module operating temperature
−30 to +75 °C
Approximate dimensions
99.5 × 112 × 22.7 mm
Warranty
18 months

About PM-TT1R single-channel PT100 RTD temperature transmitter

Overview

The PM-TT1R reads one RTD input and converts the measured temperature into standard analogue signals or digital data. PT100 is the standard input; the catalogue lists PT1000 as an optional configuration. Selectable 0–5 V, 0–10 V, 0–20 mA and 4–20 mA outputs can feed a PLC analogue input, while temperature data is also available over RS485 using Modbus RTU. The module supports two- or three-wire sensor connections. DIP switches set the analogue output type and its corresponding temperature limits. It is designed to monitor one temperature point in industrial machinery and processes.

Key features

  • One RTD input for a PT100 sensor; PT1000 is listed as an optional configuration in the catalogue.
  • Two-wire or three-wire RTD sensor connection.
  • Selectable analogue outputs: 0–5 V, 0–10 V, 0–20 mA and 4–20 mA.
  • RS485 digital output using Modbus RTU for temperature data.
  • Stated measurement accuracy: ±0.5 °C. Temperature resolution: 0.1 °C.
  • 50 Hz sampling; 15-bit ADC and 14-bit analogue output resolution, as published.
  • Catalogue and product page sensor range: −200 to +650 °C; module operating temperature: −30 to +75 °C.
  • 24 V DC supply and 1.5 W power consumption; DIP switches select the analogue output type and its temperature limits.

Benefits

  • A single RTD channel for one-point temperature measurement.
  • Choose between voltage or current analogue outputs, or read temperature over RS485 Modbus RTU.
  • Connect to a PLC analogue input or a control system that supports Modbus RTU.
  • Set the analogue output type and its corresponding temperature range with the module DIP switches.

Applications

  • Temperature measurement in furnaces and burners.
  • Temperature monitoring in machinery and packaging equipment.
  • Temperature measurement in food processing equipment and processes.
  • Ambient temperature measurement and monitoring.

Choosing an output and connecting a control system

If the PLC or controller accepts a voltage or current input, select the matching PM-TT1R output and set its temperature limits to suit the process range. For digital temperature data, use RS485 with Modbus RTU. Before ordering a PT1000 configuration or wiring the sensor, confirm the required setup against the model catalogue and manual. For four RTD measurement points, compare the four-channel PM-TT4R. For thermocouple inputs, see the single-channel PM-TT1X and four-channel PM-TT4K.

Further information

Contact the Parsmega team on WhatsApp for technical information or to discuss your requirements.

Dimensions

Temperature transmitter dimensions

Technical downloads

An English manual is not available for this product yet.

    View all documents

    Video guides

    More videos