PM-TT4R

four-channel PT100 temperature transmitter PM-TT4R

The PM-TT4R has four PT100 inputs, a display and keypad, and transfers temperature readings over RS485 Modbus RTU to compatible PLCs, HMIs and control systems. It is designed for multi-point industrial temperature monitoring.

  • RS485 communication
  • Modbus RTU communication
  • Seven-segment temperature display and keypad
  • Four RTD temperature sensor inputs
  • RS485 serial communication with Modbus RTU
  • Sensor measurement range: −200 to +650 °C
  • 15-bit analogue-to-digital converter

18-month warranty

Device specifications

Technical specifications

Controller type
Temperature
Input type
RTD
Sensor input channels
4 RTD input channels
Sensor type
PT100 RTD
Stated measurement accuracy
0.5 °C
Measurement resolution
0.1 °C
Conversion time
20 ms (50 Hz)
Analogue-to-digital converter
15 bit
Sensor measurement range
−200 to +650 °C

Mechanical specifications

Dimensions
99 × 23 × 111 mm

Serial communication

Serial communication
Yes
Serial interface
RS485
Protocol
Modbus RTU
Baud rate
2,400 to 230,400

Module operating conditions

Module operating temperature
−30 to +75 °C

Display and controls

Display
Seven-segment
Local controls
Keypad

About PM-TT4R four-channel PT100 temperature transmitter

Overview

The PM-TT4R connects to four PT100 RTD sensors for multi-point industrial temperature measurement. Typical applications include automation, HVAC and temperature-control processes.

RTDs measure temperature through predictable changes in the electrical resistance of a metal, usually platinum. For a PT100, the change per degree varies with temperature, with the source describing approximately 0.29–0.42 Ω/°C. PT500 and PT1000 sensors have different resistance changes.

The stated measurement accuracy is 0.5 °C across the RTD range, with a conversion time of 20 ms (50 Hz).

The built-in display and keypad simplify sensor and Modbus configuration. RS485 communication enables integration with compatible HMIs and PLCs as a temperature expansion module. For a single RTD input, consider the PM-TT1R.

Technical features

  • Four RTD (PT100) inputs for multi-point temperature measurement
  • Seven-segment display and keypad for local readings and configuration
  • RS485 connectivity for PLC and automation systems
  • Parsmega technical advice and after-sales support
  • Sensor measurement range: −200 to +650 °C
  • Module operating temperature: −30 to +75 °C
  • Temperature resolution: 0.1 °C
  • 15-bit analogue-to-digital converter
  • Serial baud rates from 2400 to 230400

Applications

  • Multi-point temperature monitoring in furnaces and burners
  • Temperature measurement in packaging machinery and lines
  • Temperature monitoring in food-processing equipment
  • Ambient temperature measurement in industrial monitoring systems

Benefits

  • Accurate, stable temperature measurement
  • Straightforward PLC and automation system integration
  • Clear display and easy-to-use local controls
  • Cost-conscious industrial temperature monitoring
  • Technical support and after-sales service

Choosing a model by sensor type and number of measurement points

If the project needs one PT100 input, see the single-channel PM-TT1R temperature transmitter. For thermocouple inputs, compare the single-channel PM-TT1X and four-channel PM-TT4K, depending on the number of measurement points.

Dimensions

Reference enclosure drawing. See the specifications table for the current enclosure dimensions.

Temperature transmitter dimensions

PM-TT4R frequently asked questions

How does the PM-TT4R differ from a single-channel temperature transmitter?

The PM-TT4R has four RTD inputs for measuring several points at the same time. If the project needs one PT100 input, see the single-channel PM-TT1R.

Is the PM-TT4R compatible with a Siemens PLC?

The PM-TT4R communicates over RS485 with Modbus RTU and has no analogue output.

How should I wire a PT100 sensor to the PM-TT4R?

This model is designed for a three-wire PT100 sensor. Two-wire or four-wire connections are also possible if some measurement error is acceptable. Follow the manual for the exact terminal allocation.

Technical downloads

An English manual is not available for this product yet.

    View all documents