Vibration power control from 0 to 100 percent
Vibration control with extremely high accuracy (0.1%)
Two isolated digital inputs for each channel
Analog input for each channel
Vibration power control by digital inputs
Vibration power control by analog input
Vibration power control by MODBUS serial
No need for external power tools
RS485 serial communication
Ability to connect to HMI, PLC
2 load cell inputs at the same time
24-bit analog to digital converter
Weight sampling frequency from 4.7 to 4800 Hz
4 digital inputs with user configurable functions
6 digital output (transistor) with user adjustable points
Ability to define 10 programs (profiles) for outputs
RS485 serial communication
Ability to connect to PLC, HMI and computer
Ability to calibrate with reference weight or load cell specifications
The ability to define 5 load cells and maintain the calibration of all load cells
Has a power indicator LED
Has a LED indicator for performance (Status)
2 load cell inputs at the same time
24-bit analog to digital converter
Weight sampling frequency from 4.7 to 4800 Hz
2 Analog Outputs (Voltage/Current)
Ability to specify analog output source (net weight, total weight)
Ability to scale analog output based on weight
RS485 serial communication
Ability to connect to PLC, HMI and computer
Ability to calibrate with reference weight or load cell specifications
The ability to define 5 load cells and maintain the calibration of all load cells
Has a power indicator LED
Has a LED indicator for performance (Status)
2 load cell inputs at the same time
24-bit analog to digital converter
Weight sampling frequency from 4.7 to 4800 Hz
RS485 serial communication
Ability to connect to PLC, HMI and computer
Ability to calibrate with reference weight or load cell specifications
The ability to define 5 load cells and maintain the calibration of all load cells
Has a power indicator LED
Has a LED indicator for performance (Status)
A load cell input
24-bit analog to digital converter
Weight sampling frequency from 4.7 to 4800 Hz
Isolated voltage and current analog output
Ability to specify the output analog source
Ability to scale analog output based on weight
Ability to define 10 programs (profiles) for outputs
RS485 serial communication
Ability to connect to PLC, HMI and computer
Ability to calibrate with reference weight or load cell specifications
The ability to define 5 load cells and maintain the calibration of all load cells
Has a power indicator LED
Has a LED indicator for performance (Status)
A load cell input
24-bit analog to digital converter
Weight sampling frequency from 4.7 to 4800 Hz
2 digital inputs with user configurable functions
4 digital outputs (transistor) with user adjustable points
Ability to define 10 programs (profiles) for outputs
RS485 serial communication
Ability to connect to PLC, HMI and computer
Ability to calibrate with reference weight or load cell specifications
The ability to define 5 load cells and maintain the calibration of all load cells
Has a power indicator LED
Has a LED indicator for performance (Status)
Can be installed on the rail (Din Rail)
7Segment display with the ability to display different parameters
RS485 port
Modbus RTU and Modbus ASCII protocol
3 LED displays to show different statuses
Can be installed on a rail (Din Rail)
7Segment display with the ability to display various parameters
RS485 port
Modbus RTU and Modbus ASCII protocol
Analog output 4~20mA and 0~10V
3 LED displays to show different statuses