A weight indicator receives a load cell’s low-level signal, processes it and displays the weight numerically. It is used in weighbridges, silos, tanks, hoppers, packaging, batching and production-line systems.

Depending on the model, it can also provide analogue output, Modbus communication, digital I/O and PLC/HMI integration.

How a weight indicator works

An ADC measures the load cell signal. Signal processing and filtering turn it into a calibrated weight reading. Typical functions include live indication, zero, tare, supported weighing-control operations and transfer of readings to a PLC, HMI or SCADA system.

Analogue-output models can convert weight into a signal such as 4–20 mA or 0–10 V.

Indicator versus transmitter

An indicator has a local display and usually controls for viewing and adjusting parameters. A transmitter primarily conditions the load cell measurement for analogue or digital communication to other equipment, often in a compact control-panel format.

For local operator readings, choose a suitable indicator. If the main requirement is to send weight to a PLC, a transmitter may be sufficient. Some products combine both functions, so a display is not an absolute dividing line.

Comparison of PM-LD01 weight indication with PM-LT11A and PM-LT12T load cell transmitters

The illustration compares the PM-LD01 indicator with the PM-LT11A and PM-LT12T transmitters. Output options vary: analogue, digital communication, relay or transistor functions must be checked by model.

Selection criteria

  • Load cell connections: number of cells, parallel connection and excitation requirements.
  • PLC integration: required analogue output or communication protocol.
  • Measurement performance: usable signal resolution and the complete system’s accuracy requirements.
  • Installation: panel space, ambient temperature and electrical noise.

Load cell compatibility

Rated capacity alone does not determine whether an indicator is compatible. Check the load cell output type and range, excitation and other electrical limits.

Parsmega indicators are described for standard compression, tension, bending-beam and weighbridge load cells across capacities from kilograms to tonnes, subject to the actual model specifications.

Parsmega model comparison

The LD01 family provides a larger panel format and more I/O. The LD31 family provides a compact format for restricted panel space.

Comparison from the source article; installation dimensions require confirmation against the selected model
FeaturePM-LD01PM-LD01APM-LD31PM-LD31A
ProductWeight indicatorWeight indicatorWeight indicatorWeight indicator
Source table dimensions96 × 96 × 89 mm96 × 96 × 89 mm48 × 96 × 74 mm48 × 96 × 74 mm
DisplayTwo-row 7-segmentTwo-row 7-segmentSingle-row 7-segmentSingle-row 7-segment
Relay outputs5533
Digital inputs3322
RS485 ModbusYesYesYesYes
Analogue outputNoYesNoYes
PLC connectionYesYesYesYes
Standard load cellsSupportedSupportedSupportedSupported
Typical requirementMore panel space/I/OMore I/O plus analogue outputCompact panel spaceCompact space plus analogue output
Model codePM-LD01PM-LD01APM-LD31PM-LD31A

LD01 family

The PM-LD01 and PM-LD01A have a 96 × 96 mm panel format, two display rows, five relay outputs, three digital inputs and RS485 Modbus. The source states measurement resolution of 1:100,000.

The PM-LD01 has no analogue output. The PM-LD01A adds 0–5 V, 0–10 V, 4–20 mA and 0–20 mA output options.

LD31 family

The PM-LD31 and PM-LD31A use a 48 × 96 mm panel format with a single-row display, three relay outputs, two digital inputs and RS485 Modbus.

The PM-LD31 has no analogue output; the PM-LD31A adds the standard voltage/current output ranges described above.

Which model fits the application?

Choose the LD01 family when the dual-row display and additional I/O matter. Choose the LD31 family when panel space is limited. Select an A variant when the receiving equipment requires analogue weight output. Confirm load cell compatibility, communication and the installation dimensions for the chosen model.