PM-AD04

4 independent analogue output channels
RS485 communication
Modbus RTU communication
Isolation
Analogue output
For example, PM-LT12 or load cell transmitter

PM-SS12
The PM-SS12 signal splitter and isolator converts one analogue input into two configurable analogue outputs. Output channels 1 and 2 are isolated from each other, and each can be set to 0–10 V, 0–5 V, 0–20 mA or 4–20 mA. With DIP-switch configuration, RS485 Modbus communication and DIN-rail mounting, it can route one measurement signal to two control or monitoring devices.
18-month warranty
The Parsmega PM-SS12 is an analogue signal splitter, isolator and converter for instrumentation and industrial automation. It accepts one analogue input, isolates and converts the signal, then provides two analogue outputs so one measurement can be made available to two devices or control paths at the same time.
DIP switches select the input type and the output type for each channel. The input and both outputs support 0–10 V, 0–5 V, 0–20 mA and 4–20 mA. The product description and user manual state that output channel 1 and output channel 2 are isolated from each other.
For example, a 0–10 V input can be converted to 4–20 mA on output 1 and 0–5 V on output 2. This is useful when one measurement must feed two devices with different input types. Check the signal range accepted by each destination before wiring.
The PM-SS12 provides an RS485 interface for connection to compatible PLCs, HMIs, computers and control equipment. Its user manual documents Modbus RTU and ASCII modes and selectable baud rates from 2,400 to 230,400. The serial connection can be used to read the input value and configure device parameters.
Configure the two output channels independently to match the input signal each receiving device requires.
First identify the transmitter output and select the matching input type on the PM-SS12. Then check the analogue input of each receiving device and configure output channel 1 and output channel 2 separately. For example, a 0–10 V input can be converted to 4–20 mA on channel 1 and 0–5 V on channel 2.
DIP switches 5 and 6 select the input signal; switches 3 and 4 select output channel 1, and switches 1 and 2 select output channel 2. Set the switch positions and terminals according to the tables in the manual. During initial commissioning, confirm each output signal type before connecting the load.
The terminals are grouped for the 24 V DC supply, RS485 communication, analogue input and two analogue outputs. The input has separate terminals for voltage and current signals. Each output has voltage, current and return terminals for its channel.
For terminal assignments, input and output wiring, shield connection and DIP-switch settings, consult the [PM-SS12 user manual](https://panel.parsmega.com/wp-content/uploads/2023/05/PM-SS12-Usermanual.pdf). The manufacturer recommends routing power and signal cables separately and making suitable ground and cable-shield connections.
The module has one analogue input and two analogue outputs. The outputs are isolated from each other and configured separately.
Yes. For example, with a 0–10 V input, output 1 can provide 4–20 mA while output 2 provides 0–5 V. Set both outputs to match their receiving devices.
The input and outputs support 0–10 V, 0–5 V, 0–20 mA and 4–20 mA.
DIP switches select the input and output signal types. Serial communication parameters can also be configured over RS485 as described in the manual.
The manual documents Modbus RTU and ASCII and selectable baud rates from 2,400 to 230,400. Configure the controller and module with matching serial settings.
The PM-SS12 splits one input into two analogue outputs isolated from each other. If your application needs a single isolated output, also review the PM-ISO11 signal isolator.
The specified supply is 24 V DC and the published operating temperature range is −30 to +75 °C.
For complete wiring, DIP-switch settings and serial-communication parameters, download the [PM-SS12 user manual](https://panel.parsmega.com/wp-content/uploads/2023/05/PM-SS12-Usermanual.pdf). Contact Parsmega to check compatibility with your application or request a quotation.
An English manual is not available for this product yet.